40khz 20W Ultrasonic transducer for dental scalers,Household tooth cleaner and commercial medical tooth cleaner
1-499 Piece
$6.00
500 -999 Piece
$5.50
≥ 1000 Piece
$4.80
- Item No.ARS-QXHNQ4020 PZT-4MOQ1 Piece
Choice
Quantity:
If you have your own design, please contact us, there will have a professional customer service to communicate with you.
Don't have your files right now?No worries, Check out our art tips for more information.
If over 500pcs, mass production will start until pre-production sample has been approved.
Est. 7 days production
40khz 20W Ultrasonic transducer for dental scalers,Household tooth cleaner and commercial medical tooth cleaner
Ultrasonic vibrator frequency selection technique
Ultrasonic oscillator
Everyone knows that the inside of the shock plate is composed of ultrasonic vibrators. When the cleaning machine operates at a low frequency (within the human hearing range), noise is generated. When the frequency is below 20 kHz, the working noise not only becomes very large, but may exceed the limits of safety noise as stipulated by occupational safety and health laws or other regulations. In applications where high power is required to remove dirt without regard to surface damage of the workpiece, lower cleaning machine frequencies from 20 kHz to 40 kHz are typically selected. Cleaning frequencies in this frequency range are often used to clean large, heavy-duty or high-density workpieces. The ultrasonic vibrator produced by Poda Ultrasonic has two fixed low frequency ultrasonic vibrators of 28KHZ and 40KHZ.
High frequencies are often used to clean smaller, more delicate parts or to remove tiny particles. High frequencies are also used in applications where damage is not allowed on the surface of the workpiece. The use of high frequencies improves cleaning performance in several ways. As the frequency increases, the number of cavitation bubbles increases linearly, producing more denser shock waves that allow them to enter smaller gaps. If the power remains constant, the cavitation bubbles become smaller and the energy released is correspondingly reduced, thus effectively reducing damage to the surface of the workpiece. Another advantage of high frequencies is the reduced viscous boundary layer (Ponuri effect), allowing the ultrasound to 'discover' very fine particles. And our high frequency ultrasonic vibrators are also 68KHZ, 80KHZ, 100KHZ, 120KHZ.
Specification List | ||||||
Model | Frequency (KHz) | Capacitance (pF) | Resonance Impedance (Ω) | Size Radiation head*Height (mm) | Power (W) | Insulation resistance (2500VDC) |
ARS-8QXHNQ-2540 | 40±0.8 | 3100±10% | ≤30Ω | 25*58 | 20w | ≥100MΩ |
ARS-8QXHNQ-3045 | 46±1.0 | 2400±10% | ≤25Ω | 45*43 | 35w | ≥100MΩ |
ARS-8QXHNQ-3517 | 17±1.0 | 2550±10% | ≤28Ω | 78*93 | 50w | ≥100MΩ |
ARS-8QXHNQ-3820 | 20±0.8 | 3800±10% | ≤28Ω | 59*99 | 60w | ≥100MΩ |
ARS-8QXHNQ-3823 | 23±0.8 | 3800±10% | ≤28Ω | 59*84 | 60w | ≥100MΩ |
ARS-8QXHNQ-3825* | 25±0.8 | 3800±10% | ≤20Ω | 59*80 | 60w | ≥100MΩ |
ARS-8QXHNQ-3828* | 28±0.5 | 3800±10% | ≤20Ω | 59*68 | 60w | ≥100MΩ |
ARS-8QXHNQ-3833* | 33±0.5 | 3800±10% | ≤20Ω | 48*61 | 60w | ≥100MΩ |
ARS-8QXHNQ-3840* | 40±0.5 | 3800±10% | ≤20Ω | 48*51 | 60w | ≥100MΩ |
ARS-8QXHNQ-4520* | 21.5±0.8 | 5600±10% | ≤20Ω | 67*92 | 100w | ≥100MΩ |
ARS-8QXHNQ-4528* | 28±0.5 | 5600±10% | ≤20Ω | 67*68 | 100w | ≥100MΩ |
ARS-8QXHNQ-5028 | 28±0.5 | 7200±10% | ≤20Ω | 67*68 | 120w | ≥100MΩ |
ARS-8QXHNQ-5020 | 20±0.5 | 4650±10% | ≤25Ω | 79*94 | 120w | ≥100MΩ |
ARS-4QXHNQ-2540 | 40±0.8 | 2400±10% | ≤30Ω | 25*58 | 20w | ≥100MΩ |
ARS-4QXHNQ-2540 | 40±0.8 | 2400±10% | ≤30Ω | 30*50 | 20w | ≥100MΩ |
ARS-4QXHNQ-2560 | 60±1.5 | 2300±10% | ≤35Ω | 30*35 | 20w | ≥100MΩ |
ARS-4QXHNQ-2565 | 65±1.5 | 2300±10% | ≤35Ω | 25*31 | 20w | ≥100MΩ |
ARS-4QXHNQ-3055 | 55±1.0 | 3100±10% | ≤35Ω | 30*45 | 35w | ≥100MΩ |
ARS-4QXHNQ-3050 | 52±2.0 | 3100±10% | ≤35Ω | 38*40 | 35w | ≥100MΩ |
ARS-4QXHNQ-3528* | 28 ±0.5 | 4000±10% | ≤20Ω | 45*79 | 50w | ≥100MΩ |
ARS-4QXHNQ-3540* | 40 ±1.0 | 4000±10% | ≤20Ω | 45*55 | 50w | ≥100MΩ |
ARS-4QXHNQ-3825* | 25±0.8 | 4800±10% | ≤20Ω | 59*80 | 60w | ≥100MΩ |
ARS-4QXHNQ-3828* | 28±0.5 | 4800±10% | ≤20Ω | 59*68 | 60w | ≥100MΩ |
ARS-4QXHNQ-3833 | 33±0.5 | 4800±10% | ≤20Ω | 48*62 | 60w | ≥100MΩ |
ARS-4QXHNQ-3835 | 35±0.5 | 4800±10% | ≤20Ω | 45*55 | 60w | ≥100MΩ |
ARS-4QXHNQ-3840* | 40±0.5 | 4800±10% | ≤20Ω | 48*51 | 60w | ≥100MΩ |
ARS-4QXHNQ-4520 | 22±0.5 | 7600±10% | ≤20Ω | 67*92 | 100w | ≥100MΩ |
ARS-4QXHNQ-4525 | 25±0.5 | 7600±10% | ≤20Ω | 67*76 | 100w | ≥100MΩ |
ARS-4QXHNQ-4528* | 28±0.5 | 7600±10% | ≤20Ω | 67*68 | 100w | ≥100MΩ |
ARS-4QXHNQ-4540* | 40±0.5 | 7600±10% | ≤20Ω | 55*53 | 100w | ≥100MΩ |
ARS-4QXHNQ-5028 | 28±0.5 | 9600±10% | ≤20Ω | 67*68 | 120w | ≥100MΩ |
ARS-4QXHNQ-3868 | 67±2.0 | 4800±10% | ≤20Ω | 50*65 | 50w | ≥100MΩ |
ARS-4QXHNQ-3880 | 79±1.5 | 4800±10% | ≤25Ω | 40*54 | 60w | ≥100MΩ |
ARS-4QXHNQ-38100 | 100±1.5 | 4800±10% | ≤25Ω | 40*57 | 60w | ≥100MΩ |
ARS-4QXHNQ-38120 | 120±1.5 | 4800±10% | ≤25Ω | 40*58 | 60w | ≥100MΩ |
ARS-4QXHNQ-35130 | 129±1.5 | 4200±10% | ≤25Ω | 36*54 | 50w | ≥100MΩ |
ARS4QXHNQ-38160 | 160±1.5 | 4800±10% | ≤25Ω | 40*57 | 60w | ≥100MΩ |
ARS-4AS-35165 | 165±5.0 | 4100±10% | ≤60Ω | 42*61 | 40w | ≥100MΩ |
ARS-4AH-25200 | 200±2.0 | 2300±10% | ≤35Ω | 30*35 | 20w | ≥100MΩ |
Screw hole size (diameter * pitch * depth)M10*1.0*10 |
40khz 20W Ultrasonic transducer for dental scalers,Household tooth cleaner and commercial medical tooth cleaner
Send your message to us
No need register, just fill in contact info below, we will reply you within 24 hours!