Made In China Ultrasonic Full Touch Screen Impedance Analyzer and Frequency Analyzer

Message

$2,850.00

Have chosenThere are no options selected.

Start To Order

Add To Cart Successfully!

SEND INQUIRY
Made In China Ultrasonic Full Touch Screen Impedance Analyzer and Frequency Analyzer

Made In China Ultrasonic Full Touch Screen Impedance Analyzer and Frequency Analyzer

  • Item No. 20201126f3d21
    MOQ 1 Set
  • Product size 55 x 55 x 60 cm
    Product weight 25 kg
Tag   wholesale
Add Request About This Product
Max file 5MB each
If lager file please send us email

Quantity:

From $ 2850.002650.00  / Set
$ 2,850.00
You save  $  -2,850.00
Trade Assurance protects your orders
On-time Dispatch Guarantee
On-time dispatch is guaranteed or you will be eligible to claim platform compensation.
Refund Policy
If the shipment is delayed or product quality differs from what are specified in the online order, you can claim for a refund.
Quick refund: If you can apply for a refund within two hours of making a payment, you will receive a refund immediately.

If you have your own design, please contact us, there will have a professional customer service to communicate with you.

Don't have your files right now?No worries, Check out our art tips for more information.

If over 500pcs, mass production will start until pre-production sample has been approved.

Est. 7 days production

Made In China Ultrasonic Full Touch Screen Impedance Analyzer and Frequency Analyzer

 

----_02.jpg

Impedance analyzer

Application: all kinds of ultrasound parts testing: piezoelectric ceramic, transducer, ultrasonic cleaner,              ultrasonic plastic welding machine, water sound, magnetostrictive material, ultrasonic disintegrator,                ultrasonic atomizing, ultrasonic tooth cleaner, distance sensor,ultrasonic emulsification, ultrasonic descaling,        ultrasonic motor, and all other piezoelectric and ultrasonic equipment and device.     

 

In the ultrasound testing, the admittance circle diagram and logarithmic diagram are very important, because these  two diagrams is the main method to adjusting qualified. This instrument has below parameters:  resonance frequency (Fs),maximum conductance (Gmax),bandwidth(F2-F1),antiresonance frequency (Fp),        quality factor(Qm),Free capacitor (CT),dynamic resistance (R1),dynamic inductance (L1),dynamic            capacity (C1),direst capacitance (C0),effective electro-mechanical couple factor(Keff),planar            electromechanical coupling factor(Kp), free dielectric constant. 

 

 

The software specially designed for ultrasound applications makes it more convenient and simpler to use than imported instruments in the application. It does not require professional operations and can calculate more parameters.

 

Users can store and print any graphics, and can save the parameters as a computer Excel table, which greatly improves the convenience of users. Users can also customize the qualification conditions themselves, and the software can automatically determine the qualification.

 

The system provides a dozen parameters, the average user is commonly used the following parameters:

Fs: mechanical resonant frequency, that is the operating frequency of the vibration system, the design should be as close to the expected value, and must match the power supply point.

R1: dynamic resistance, the piezoelectric vibrator series branch resistor, the internal resistance of the device is, the greater the resistance, the higher the power loss of energy.

Qm: mechanical quality factor, Qm, the higher electro-acoustic transducer conversion efficiency, but also the more narrow bandwidth transducer, generally moderate better.

CT: freedom capacitors, piezoelectric device capacitance value at 1kHz frequency, this value is subtracted dynamic capacitance C1 can get real capacitance C0.

Fp: anti-resonance frequency, the piezoelectric oscillator resonant frequency of parallel branches.

 

 

ypeMeasuring FrequencyBasic AccuracyMeasuring ProductFeature
ARS-ZKFXY5001KHz-500KHz<0.1%ultrasonic transducer,piezoelectric ceramicdisplay
ARS-ZKFXY10001KHz-1MHz<0.1%ultrasonic transducer,piezoelectric ceramicdisplay
ARS-ZKFXY30001KHz-3MHz<0.1%ultrasonic transducer,piezoelectric ceramicdisplay

 

 

 

 

2.jpg1.jpg

Correct testing transducer mode as below:

Note transducer placed posture, usually lying down on the cushion, put the wrong posture can lead to
inaccurate measurements

1.png

 

This instrument can provide the following coordinate characteristic diagram. 


the admittance circle diagram GBF coordinate curve: Left curve: horizontal ordinate--admittance circle real part G, vertical coordinate--admittance circle imaginary part B. Right curve: Red--admittance circle real part G, blue--admittance circle imaginary part B. vertical coordinate--frequency

 111.jpg

 

 

Impedance coordinate RXF coordinate curve: Left curve: horizontal ordinate --impedance real part R, vertical coordinate-- impedance imaginary part X Right curve:Red--impedance real part R, Blue--impedance imaginary part, vertical coordinate--frequency 

 

 222.jpg

 

 

 

The system provides a dozen parameters, the average user is commonly used the following parameters:
 
Fs: mechanical resonant frequency, that is the operating frequency of the vibration system, the design should be as close to the expected value, and must match the power supply point.
R1: dynamic resistance, the piezoelectric vibrator series branch resistor, the internal resistance of the device is, the greater the resistance, the higher the power loss of energy.
Qm: mechanical quality factor, Qm, the higher electro-acoustic transducer conversion efficiency, but also the more narrow bandwidth transducer, generally moderate better.
CT: freedom capacitors, piezoelectric device capacitance value at 1kHz frequency, this value is subtracted dynamic capacitance C1 can get real capacitance C0.
Fp: anti-resonance frequency, the piezoelectric oscillator resonant frequency of parallel branches.
Measurement graph as follows: due between the start and stop frequencies did not contain the anti-resonant frequency of the device.
Workaround: terminate an appropriate increase in frequency.
 

 

 