With Nails Ultrasonic Piezoelectric Transducer 40KHZ 50W For Making Korean Table Ultrasound Cleaner Tank

Message

$6.50

Have chosenThere are no options selected.

Start To Order

Add To Cart Successfully!

SEND INQUIRY
With Nails Ultrasonic Piezoelectric Transducer 40KHZ 50W For Making Korean Table Ultrasound Cleaner Tank
With Nails Ultrasonic Piezoelectric Transducer 40KHZ 50W For Making Korean Table Ultrasound Cleaner Tank
With Nails Ultrasonic Piezoelectric Transducer 40KHZ 50W For Making Korean Table Ultrasound Cleaner Tank
With Nails Ultrasonic Piezoelectric Transducer 40KHZ 50W For Making Korean Table Ultrasound Cleaner Tank
With Nails Ultrasonic Piezoelectric Transducer 40KHZ 50W For Making Korean Table Ultrasound Cleaner Tank
With Nails Ultrasonic Piezoelectric Transducer 40KHZ 50W For Making Korean Table Ultrasound Cleaner Tank
With Nails Ultrasonic Piezoelectric Transducer 40KHZ 50W For Making Korean Table Ultrasound Cleaner Tank

With Nails Ultrasonic Piezoelectric Transducer 40KHZ 50W For Making Korean Table Ultrasound Cleaner Tank

  • Item No.ARS-4QXHNQ-3540*
    MOQ1 Piece
  • Product size45 x 35 x 57 cm
    Product weight3 kg
Tag  wholesale
Add Request About This Product
Max file 5MB each
If lager file please send us email

Quantity:

From $6.506.005.00 / Piece
$6.50
You save $ -6.50
Trade Assuranceprotects your orders
On-time Dispatch Guarantee
On-time dispatch is guaranteed or you will be eligible to claim platform compensation.
Refund Policy
If the shipment is delayed or product quality differs from what are specified in the online order, you can claim for a refund.
Quick refund: If you can apply for a refund within two hours of making a payment, you will receive a refund immediately.

If you have your own design, please contact us, there will have a professional customer service to communicate with you.

Don't have your files right now?No worries, Check out our art tips for more information.

If over 500pcs, mass production will start until pre-production sample has been approved.

Est. 7 days production

02Specification

Introduction to ultrasonic transducer:

The ultrasonic vibrator, also called the ultrasonic vibrating head, is an ultrasonic transducer and is the core component of the ultrasonic cleaning machine. The whole of the ultrasonic transducer connected to the horn is called a vibrator. Ultrasonic transducer is one of the important components in ultrasonic cleaning machine and ultrasonic vibration plate, which largely determines the quality of ultrasonic effect.

Based on years of experience in ultrasonic cleaning, our company provides professional ultrasonic transducers with stable quality, high efficiency output and moderate price based on the opinions and feedback of users.

An ultrasonic transducer is a device that converts high-frequency electrical energy into mechanical vibration. The high-frequency electrical energy input by the ultrasonic generator matches the piezoelectric ceramic piece with the resonant frequency of the ultrasonic transducer, and the piezoelectric effect of the material is used to convert the electrical energy. It is converted into mechanical vibration, that is, ultrasonic vibration, which is transmitted to the water medium through the ultrasonic transducer, and forms negative pressure bubbles and shock waves in the water, and is transmitted in the tax base solution to achieve the effect of cleaning the surface of the workpiece. The transducer is mainly composed of an aluminum block, a piezoelectric ceramic piece and an insulating layer.

 

 

Ultrasonic Transducer classification:

A. piezoelectric chip classification: Black chip P4 series and yellow chip P8 series;

B. Frequency classification: low frequency series (17-23KHz), intermediate frequency series (25-28KHz), medium and high frequency series (33-60KHz) and high frequency series (68-200KHz);

C. Power classification: 30W series (including 35W), 50W series (including 60W), 100W series (including 80W) and other unconventional power;

D. shape classification: straight column and horn type

 

Ultrasonic Transducer Frequency selection:

The frequency of the transducer is inversely proportional to the wavelength, and the wavelength is related to the diameter of the cavity (strictly speaking, the nucleation time is longer due to the low frequency), and the diameter of the cavity is related to the explosion pressure. The higher the general frequency, the smaller the wavelength, the smaller the diameter of the cavity, the lower the explosion pressure, but the higher the density of the cavity, the better the permeability.

 

Based on the above principles:

Low frequency (17 ~ 23KHz): When the dirt of the cleaned material is heavy or difficult to be cleaned, and the explosive impact does not cause much damage to the surface of the cleaned material, the low frequency series transducer should be selected. Commonly used industries are: magnetic industry, steam protection industry, textile industry and so on. Note that the noise of this series is large, preferably sound insulation.

 

Medium frequency (25 ~ 28KHz): If the dirt of the cleaned material is slightly heavy or the cleaning is difficult and moderate, and the explosive impact does not cause much damage to the surface of the cleaned material, the intermediate frequency series transducer should be selected. This series of industries are the most widely used, and are common in machinery processing industry, electroplating industry, catering industry and so on.

 

Medium and high frequency (33 ~ 60KHz): When the dirt of the cleaned material is light, the cleaning is easy, or the explosive shock damage to the surface of the cleaned material is required, the medium and high frequency series transducer should be selected. Commonly used industries include precision parts, glass glasses, electronic components, circuit boards, etc.

 

High Frequency (68-200KHz): The dirt is very light and easy to clean. When the explosive impact is prohibited to damage the surface of the cleaned object, the high frequency series transducer should be selected. Commonly used industries are semiconductors, special high-precision parts, etc.

Specification List 
ModelFrequency
(KHz)
  Capacitance
(pF)
Resonance
Impedance
(Ω)
   Size 
Radiation
head*Height
 (mm)
 Power
(W)
 Insulation
resistance
(2500VDC)
ARS-8QXHNQ-254040±0.83100±10%≤30Ω25*5820w≥100MΩ
ARS-8QXHNQ-304546±1.02400±10%≤25Ω45*4335w≥100MΩ
ARS-8QXHNQ-351717±1.02550±10%≤28Ω78*9350w≥100MΩ
ARS-8QXHNQ-382020±0.83800±10%≤28Ω59*9960w≥100MΩ
ARS-8QXHNQ-382323±0.83800±10%≤28Ω59*8460w≥100MΩ
ARS-8QXHNQ-3825*25±0.83800±10%≤20Ω59*8060w≥100MΩ
ARS-8QXHNQ-3828*28±0.53800±10%≤20Ω59*6860w≥100MΩ
ARS-8QXHNQ-3833*33±0.53800±10%≤20Ω48*6160w≥100MΩ
ARS-8QXHNQ-3840*40±0.53800±10%≤20Ω48*5160w≥100MΩ
ARS-8QXHNQ-4520*21.5±0.85600±10%≤20Ω67*92100w≥100MΩ
ARS-8QXHNQ-4528*28±0.55600±10%≤20Ω67*68100w≥100MΩ
ARS-8QXHNQ-502828±0.57200±10%≤20Ω67*68120w≥100MΩ
ARS-8QXHNQ-502020±0.54650±10%≤25Ω79*94120w≥100MΩ
ARS-4QXHNQ-254040±0.82400±10%≤30Ω25*5820w≥100MΩ
ARS-4QXHNQ-254040±0.82400±10%≤30Ω30*5020w≥100MΩ
ARS-4QXHNQ-256060±1.52300±10%≤35Ω30*3520w≥100MΩ
ARS-4QXHNQ-256565±1.52300±10%≤35Ω25*3120w≥100MΩ
ARS-4QXHNQ-305555±1.03100±10%≤35Ω30*4535w≥100MΩ
ARS-4QXHNQ-305052±2.03100±10%≤35Ω38*4035w≥100MΩ
ARS-4QXHNQ-3528*28 ±0.54000±10%≤20Ω45*7950w≥100MΩ
ARS-4AH-3540*40 ±1.04000±10%≤20Ω45*5550w≥100MΩ
ARS-4QXHNQ-3825*25±0.84800±10%≤20Ω59*8060w≥100MΩ
ARS-4QXHNQ-3828*28±0.54800±10%≤20Ω59*6860w≥100MΩ
ARS-4QXHNQ-383333±0.54800±10%≤20Ω48*6260w≥100MΩ
ARS-4QXHNQ-383535±0.54800±10%≤20Ω45*5560w≥100MΩ
ARS-4QXHNQ-3840*40±0.54800±10%≤20Ω48*5160w≥100MΩ
ARS-4QXHNQ-452022±0.57600±10%≤20Ω67*92100w≥100MΩ
ARS-4QXHNQ-452525±0.57600±10%≤20Ω67*76100w≥100MΩ
ARS-4QXHNQ-4528*28±0.57600±10%≤20Ω67*68100w≥100MΩ
ARS-4QXHNQ-4540*40±0.57600±10%≤20Ω55*53100w≥100MΩ
ARS-4QXHNQ-502828±0.59600±10%≤20Ω67*68120w≥100MΩ
ARS-4QXHNQ-386867±2.04800±10%≤20Ω50*6550w≥100MΩ
ARS-4QXHNQ-388079±1.54800±10%≤25Ω40*5460w≥100MΩ
ARS-4QXHNQ-38100100±1.54800±10%≤25Ω40*5760w≥100MΩ
ARS-4QXHNQ-38120120±1.54800±10%≤25Ω40*5860w≥100MΩ
ARS-4QXHNQ-35130129±1.54200±10%≤25Ω36*5450w≥100MΩ
ARS4QXHNQ-38160160±1.54800±10%≤25Ω40*5760w≥100MΩ
ARS-4AS-35165165±5.04100±10%≤60Ω42*6140w≥100MΩ
ARS-4AH-25200200±2.02300±10%≤35Ω30*3520w≥100MΩ
Screw hole size (diameter * pitch * depth)M10*1.0*10

04Product display

IMG_1137.jpgIMG_1168.jpgIMG_1001 .JPG

.jpg

 The Process Flow_01

 

Why choose us and About us

 

 

 

 

 

 

 Certicate.jpg

 

 Shiping and Packing.jpg

Shiping.jpg

Transducer packing.jpg

 

 FAQ

Send your message to us

No need register, just fill in contact info below, we will reply you within 24 hours!

Please prove you are human by selecting the "Heart".