Industrial Cleaner Transducer Elements 70KHZ Single&High Frequency Ultrasonic Piezoelectric Oscillator Cleaning Oscillation
  • Item No.ARS-4QXHNQ-3870
    MOQ1 Piece / Pieces
    description

    Industrial Cleaner Transducer Elements 70KHZ Single&High Frequency Ultrasonic Piezoelectric Oscillator  Cleaning Oscillation

    02Specification

    Ultrasonic transducers are piezoelectric ceramics that resonate at ultrasonic frequencies and convert electrical signals into mechanical vibrations by the piezoelectric effect of the material. Medical ultrasonic transducers (ultrasonic probes) operate in much the same way, and typically contain an electrical energy storage element and a mechanical vibration system inside. When the transducer is used as a transmitter, the electrical oscillating signal sent from the excitation source will cause a change in the electric or magnetic field in the electrical energy storage element of the transducer, which changes the mechanical vibration system of the transducer through some effect. A driving force is generated to cause it to vibrate, thereby propelling the medium in contact with the mechanical vibration system of the transducer to vibrate and radiate sound waves into the medium. The process of receiving sound waves is exactly the opposite. External sound waves act on the vibrating surface of the transducer, causing the mechanical vibration system of the transducer to vibrate, causing an electric field in the energy storage element of the transducer or by some physical effect. The magnetic field changes accordingly, causing the electrical output of the transducer to produce a voltage and current corresponding to the acoustic signal.

     

    Ultrasonic Transducer classification:

    A. piezoelectric chip classification: Black chip P4 series and yellow chip P8 series;

     

    B. Frequency classification: low frequency series (17-23KHz), intermediate frequency series (25-28KHz), medium and high frequency series (33-60KHz) and high frequency series (68-200KHz);

     

    C. Power classification: 30W series (including 35W), 50W series (including 60W), 100W series (including 80W) and other unconventional power;

     

    D. shape classification: straight column and horn type

     

     

    Specification List 
    ModelFrequency
    (KHz)
      Capacitance
    (pF)
    Resonance
    Impedance
    (Ω)
       Size 
    Radiation
    head*Height
     (mm)
     Power
    (W)
     Insulation
    resistance
    (2500VDC)
    ARS-8QXHNQ-254040±0.83100±10%≤30Ω25*5820w≥100MΩ
    ARS-8QXHNQ-304546±1.02400±10%≤25Ω45*4335w≥100MΩ
    ARS-8QXHNQ-351717±1.02550±10%≤28Ω78*9350w≥100MΩ
    ARS-8QXHNQ-382020±0.83800±10%≤28Ω59*9960w≥100MΩ
    ARS-8QXHNQ-382323±0.83800±10%≤28Ω59*8460w≥100MΩ
    ARS-8QXHNQ-3825*25±0.83800±10%≤20Ω59*8060w≥100MΩ
    ARS-8QXHNQ-3828*28±0.53800±10%≤20Ω59*6860w≥100MΩ
    ARS-8QXHNQ-3833*33±0.53800±10%≤20Ω48*6160w≥100MΩ
    ARS-8QXHNQ-3840*40±0.53800±10%≤20Ω48*5160w≥100MΩ
    ARS-8QXHNQ-4520*21.5±0.85600±10%≤20Ω67*92100w≥100MΩ
    ARS-8QXHNQ-4528*28±0.55600±10%≤20Ω67*68100w≥100MΩ
    ARS-8QXHNQ-502828±0.57200±10%≤20Ω67*68120w≥100MΩ
    ARS-8QXHNQ-502020±0.54650±10%≤25Ω79*94120w≥100MΩ
    ARS-4QXHNQ-254040±0.82400±10%≤30Ω25*5820w≥100MΩ
    ARS-4QXHNQ-254040±0.82400±10%≤30Ω30*5020w≥100MΩ
    ARS-4QXHNQ-256060±1.52300±10%≤35Ω30*3520w≥100MΩ
    ARS-4QXHNQ-256565±1.52300±10%≤35Ω25*3120w≥100MΩ
    ARS-4QXHNQ-305555±1.03100±10%≤35Ω30*4535w≥100MΩ
    ARS-4QXHNQ-305052±2.03100±10%≤35Ω38*4035w≥100MΩ
    ARS-4QXHNQ-3528*28 ±0.54000±10%≤20Ω45*7950w≥100MΩ
    ARS-4QXHNQ-3540*40 ±1.04000±10%≤20Ω45*5550w≥100MΩ
    ARS-4QXHNQ-3825*25±0.84800±10%≤20Ω59*8060w≥100MΩ
    ARS-4QXHNQ-3828*28±0.54800±10%≤20Ω59*6860w≥100MΩ
    ARS-4QXHNQ-383333±0.54800±10%≤20Ω48*6260w≥100MΩ
    ARS-4QXHNQ-383535±0.54800±10%≤20Ω45*5560w≥100MΩ
    ARS-4QXHNQ-3840*40±0.54800±10%≤20Ω48*5160w≥100MΩ
    ARS-4QXHNQ-452022±0.57600±10%≤20Ω67*92100w≥100MΩ
    ARS-4QXHNQ-452525±0.57600±10%≤20Ω67*76100w≥100MΩ
    ARS-4QXHNQ-4528*28±0.57600±10%≤20Ω67*68100w≥100MΩ
    ARS-4QXHNQ-4540*40±0.57600±10%≤20Ω55*53100w≥100MΩ
    ARS-4QXHNQ-502828±0.59600±10%≤20Ω67*68120w≥100MΩ
    ARS-4QXHNQ-386867±2.04800±10%≤20Ω50*6550w≥100MΩ
    ARS-4QXHNQ-388079±1.54800±10%≤25Ω40*5460w≥100MΩ
    ARS-4QXHNQ-38100100±1.54800±10%≤25Ω40*5760w≥100MΩ
    ARS-4QXHNQ-38120120±1.54800±10%≤25Ω40*5860w≥100MΩ
    ARS-4QXHNQ-35130129±1.54200±10%≤25Ω36*5450w≥100MΩ
    ARS4QXHNQ-38160160±1.54800±10%≤25Ω40*5760w≥100MΩ
    ARS-4AS-35165165±5.04100±10%≤60Ω42*6140w≥100MΩ
    ARS-4AH-25200200±2.02300±10%≤35Ω30*3520w≥100MΩ
    Screw hole size (diameter * pitch * depth)M10*1.0*10

     

    04Product display

    IMG_1127.jpgIMG_1168.jpgIMG_1001 .JPG

    .jpg

    The Process Flow_01

    Why choose us and About usCertificationShiping and Packing.jpg

    Shiping.jpg

    Transducer packing.jpg

     

     FAQ

    Have more questions about this product?

    Scan the QR code with your phone, or visit the URL

    https://www.digitalultrasoniccleaner.com/

    Have more questions about this product?
    • 506B,Dazhong industry park,sanhe ,DaLang street,longhua district,ShenZhen China
    • 86-13662219669
    • [email protected]